|
|
Emerson Process Management
DeltaV & AMS Suite: Intelligent Device Manager |
|
| Category: |
Host |
 |
| Revision: |
DeltaV 10.3 & AMS 10.5 |
| Host Registration Date: |
04/24/2009 |
| System Components: |
DeltaV Workstation - 10.3
DeltaV MD Controller - 10.3
DeltaV Fieldbus H1 Card - 4.86
AMS Suite: Intelligent Device Manager - 10.5
|
| Test Campaign Number: |
HP061300 |
| Tester Version: |
2.1 |
| Test Status: |
Registered |
| |
| Stack |
| Manufacturer (H1): |
Emerson Process Management |
| Revision (H1): |
4.86 |
| Test Campaign Number (H1): |
CT0056FF |
| Manufacturer (HSE): |
NA |
| Revision (HSE): |
NA |
| Test Campaign Number (HSE): |
NA |
| |
| Physical Layer |
| Physical Layer types: |
113 - Standard-power signaling, bus-powered, non I.S. |
| Test Campaign Number: |
PT-299 |
| |
| Foundation Host Profile Details |
| Foundation Host Profile: |
Class 61a – Integrated Host |
Additional FOUNDATION Host Profiles: Click to view Other Profiles |
|
| Host Interface Type Supported: |
H1 Interface |
| Communication Profile Class: |
31PS, 32LT |
| |
Host Profile
Supported Features |
| H1 Device Support: |
H1 Device Address Assignment
Configuration of Link Master Devices
H1 Physical Device Tag Assignment
Convert Link Master to Basic Device
H1 Software Download |
| HSE Support: |
Not Supported |
| Distributed Application Support: |
Block Tag Configuration
Resource and Transducer Blocks
Standard Function Blocks
Configuration of scheduled control function blocks
Function Block Linking and Publication Scheduling
Function Block Execution Scheduling
Use Views for Block Detail Reads |
| Alert Configuration and Handling: |
Device Alert Management Configuration
Device Alert Handling and Confirmation |
| Device Description Support: |
DD Blocks and Parameters
DD v4 Methods execution
DD v4 Menus
DD v5 Visualizations, Methods
DD v5 Persistent data
Capability File Support |
| Data Quality Support: |
Data Quality display in default block detail displays
Data Quality Display in Default Face-Plate Displays
Data Quality Display in Trending
Data Quality Support through Host Controller Connections
Data Quality Recording in Historian
Data Quality Display in Custom Process Graphics |
| |
| Previous Registrations |
Previous Revisions: Click to view Previous Versions |
|
| More Information: |
The DeltaV system and AMS Device Manager software are built for Foundation fieldbus and provide global process manufacturers predictive information to improve their plant's performance.
|
| Contact Name: |
DeltaV Marketing Team |
| Telephone: |
+1 512.835.2190 |
| E-mail: |
This e-mail address is being protected from spam bots, you need JavaScript enabled to view it
|
| Website: |
http://www2.emersonprocess.com/en-US/contacts/Pages/ContactUs.aspx |
| Last updated: |
2010-07-14 11:38:32 |